Aim-TTi 1908P Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max

Nº de Estoque RS: 123-8854Marca: Aim-TTiPart Number: 1908P
brand-logo
View all in Multimeters

Documentos Técnicos

Especificações

Brand

Aim-TTi

Multimeter Type

Bench

Model Number p

1908P

Display Type

Digital

Functions Measured

AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature

Absolute Maximum AC Current Measurement

10A ac

Absolute Maximum Resistance Measurement

1kΩ

Absolute Maximum AC Voltage Measurement

1000V ac

Absolute Maximum DC Current Measurement

10A dc

Absolute Maximum DC Voltage Measurement

1000V dc

Absolute Maximum Capacitance Measurement

100µF

Absolute Maximum Temperature Measurement

+400°C

Maximum Frequency

100kHz

AC Current Measurement Resolution

100nA ac

DC Current Measurement Resolution

100nA dc

Resistance Measurement Resolution

1mΩ

DC Voltage Measurement Resolution

1µV dc

AC Voltage Measurement Resolution

1µV ac

Capacitance Measurement Resolution

10pF

Temperature Measurement Resolution

0.1°C

Safety Category Level

CAT II

Best AC Current Accuracy

0.35 %

Width

235mm

Length

260mm

Dimensions

260 x 235 x 88mm

Best DC Voltage Accuracy

0.02 %

Best Capacitance Measurement Accuracy

2 %

Minimum Operating Temperature

+5°C

Height

88mm

Weight

2kg

Best Temperature Measurement Accuracy

0.05 %

Best AC Voltage Accuracy

0.3 %

Safety Category Voltage

600V

Battery Type

Rechargeable NiMH

Best DC Current Accuracy

0.05 %

Best Resistance Measurement Accuracy

0.05 %

Maximum Operating Temperature

+40°C

País de Origem

United Kingdom

Detalhes do produto

Aim-TTI 1908P Series Dual Measurement Bench Multimeter

Aim-TTi 1908 Series is a dual measurement, dual display bench-top/portable multimeter. It features continuity and diode test, automatic or manual ranging, linear scaling with offset, dB measurements, limits comparison, percentage deviation (%), min-max storage, power measurement in watts or VA, automatic data logging and external triggering. The logger function can store up to 500 readings from the main display in non-volatile memory. The two displays can be used to display a measurement along with the selected range (e.g. 100 Vdc), a measurement in two different units (e.g. AC volts and dBm), the result of a calculated function (e.g. value and % deviation), two parameters of one signal (e.g. AC and DC volts) or two different signals (e.g. AC volts and DC current). Software 1908-PC Link provides remote control of main functions and logging function with graphical and tabular displays (logged data can be exported to a CSV file). Model 1908P can be remotely controlled via its RS232, USB or LAN interface. Model 1908 (non ’P’) can only be controlled via USB.
For an optional GPIB module see stock number 144-5481.

Supplied with

IVI driver, LV/CVI driver, USB driver

Standards

EN61010-1, EN61010-2-030 & EN61010-2-033, EN61326-1 EMC

Informações de estoque temporariamente indisponíveis.

Verifique novamente mais tarde.

Informações de estoque temporariamente indisponíveis.

R$ 15.716,16

Each (Sem VAT)

Aim-TTi 1908P Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max

R$ 15.716,16

Each (Sem VAT)

Aim-TTi 1908P Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
Informações de estoque temporariamente indisponíveis.

Documentos Técnicos

Especificações

Brand

Aim-TTi

Multimeter Type

Bench

Model Number p

1908P

Display Type

Digital

Functions Measured

AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature

Absolute Maximum AC Current Measurement

10A ac

Absolute Maximum Resistance Measurement

1kΩ

Absolute Maximum AC Voltage Measurement

1000V ac

Absolute Maximum DC Current Measurement

10A dc

Absolute Maximum DC Voltage Measurement

1000V dc

Absolute Maximum Capacitance Measurement

100µF

Absolute Maximum Temperature Measurement

+400°C

Maximum Frequency

100kHz

AC Current Measurement Resolution

100nA ac

DC Current Measurement Resolution

100nA dc

Resistance Measurement Resolution

1mΩ

DC Voltage Measurement Resolution

1µV dc

AC Voltage Measurement Resolution

1µV ac

Capacitance Measurement Resolution

10pF

Temperature Measurement Resolution

0.1°C

Safety Category Level

CAT II

Best AC Current Accuracy

0.35 %

Width

235mm

Length

260mm

Dimensions

260 x 235 x 88mm

Best DC Voltage Accuracy

0.02 %

Best Capacitance Measurement Accuracy

2 %

Minimum Operating Temperature

+5°C

Height

88mm

Weight

2kg

Best Temperature Measurement Accuracy

0.05 %

Best AC Voltage Accuracy

0.3 %

Safety Category Voltage

600V

Battery Type

Rechargeable NiMH

Best DC Current Accuracy

0.05 %

Best Resistance Measurement Accuracy

0.05 %

Maximum Operating Temperature

+40°C

País de Origem

United Kingdom

Detalhes do produto

Aim-TTI 1908P Series Dual Measurement Bench Multimeter

Aim-TTi 1908 Series is a dual measurement, dual display bench-top/portable multimeter. It features continuity and diode test, automatic or manual ranging, linear scaling with offset, dB measurements, limits comparison, percentage deviation (%), min-max storage, power measurement in watts or VA, automatic data logging and external triggering. The logger function can store up to 500 readings from the main display in non-volatile memory. The two displays can be used to display a measurement along with the selected range (e.g. 100 Vdc), a measurement in two different units (e.g. AC volts and dBm), the result of a calculated function (e.g. value and % deviation), two parameters of one signal (e.g. AC and DC volts) or two different signals (e.g. AC volts and DC current). Software 1908-PC Link provides remote control of main functions and logging function with graphical and tabular displays (logged data can be exported to a CSV file). Model 1908P can be remotely controlled via its RS232, USB or LAN interface. Model 1908 (non ’P’) can only be controlled via USB.
For an optional GPIB module see stock number 144-5481.

Supplied with

IVI driver, LV/CVI driver, USB driver

Standards

EN61010-1, EN61010-2-030 & EN61010-2-033, EN61326-1 EMC