Documentos Técnicos
Especificações
Brand
Phoenix ContactSupply Voltage
24V ac/dc
Number of Channels
2
Safety Contacts
4
Function
Emergency Stop
Reset Method
Automatic & Manual
Range
PSRclassic
Safety Category ISO 13849-1
4
Safety Category (ISO 13849-1)
4
PL ISO 13849-1
e
PL (ISO 13849-1)
e
SIL IEC 61508
3
SIL (IEC 61508)
3
Terminal Type
Push In
Configurable
Yes
Standards Met
CE
Series
PSR-SPP- 24UC/ESL4/3X1/1X2/B
Width
22.5mm
Depth
114.5mm
Performance Level
e
Length
117mm
País de Origem
Germany
Detalhes do produto
PSR Safety Relay for Light Grids
The PSR safety relays from Phoenix Contact have a supply voltage of 24 Vac/dc and are for light grid monitoring, emergency stop (E-Stop) and safety door monitoring. Relevant safety equipment can be connected easily without the need for additional settings on the relay.
Standards
Up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508.
Informações de estoque temporariamente indisponíveis.
Verifique novamente mais tarde.
R$ 4.241,39
Each (Sem VAT)
1
R$ 4.241,39
Each (Sem VAT)
1
Comprar em grandes quantidades
Quantidade | Preço unitário |
---|---|
1 - 4 | R$ 4.241,39 |
5 - 9 | R$ 4.187,09 |
10+ | R$ 4.135,52 |
Documentos Técnicos
Especificações
Brand
Phoenix ContactSupply Voltage
24V ac/dc
Number of Channels
2
Safety Contacts
4
Function
Emergency Stop
Reset Method
Automatic & Manual
Range
PSRclassic
Safety Category ISO 13849-1
4
Safety Category (ISO 13849-1)
4
PL ISO 13849-1
e
PL (ISO 13849-1)
e
SIL IEC 61508
3
SIL (IEC 61508)
3
Terminal Type
Push In
Configurable
Yes
Standards Met
CE
Series
PSR-SPP- 24UC/ESL4/3X1/1X2/B
Width
22.5mm
Depth
114.5mm
Performance Level
e
Length
117mm
País de Origem
Germany
Detalhes do produto
PSR Safety Relay for Light Grids
The PSR safety relays from Phoenix Contact have a supply voltage of 24 Vac/dc and are for light grid monitoring, emergency stop (E-Stop) and safety door monitoring. Relevant safety equipment can be connected easily without the need for additional settings on the relay.
Standards
Up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508.