Documentos Técnicos
Especificações
Brand
PR ElectronicsInput Type
Linear Resistance, RTD
Supply Voltage
8 → 35 V dc
Minimum Temperature Input
-200°C
Maximum Temperature Input
850°C
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+60°C
Series
6300
Depth
104mm
Hazardous Area Certification
ATEX
País de Origem
Denmark
Detalhes do produto
6333A - 2-wire Programmable Transmitter
PR Electronics 6333A 2-wire programmable temperature transmitter offers unrivalled performance in applications making heavy demands on accuracy to convert a wide array of input types to a 4 – 20 mA output signal. The 6333 transmitters provides unrivalled input versatility with galvanic isolation up to 1.5 kVAC for 2 & 3 Wire RTD and linear resistance signals. Input sensor redundancy function maintains process availability and safety in the event of primary sensor failure
The 6300 series transmitters are quickly and easily programmable to the specific application. Configuration via a standard PC and user-friendly software, PReset, available as a free download. Parameters for input, output, sensor error detection and process calibration can be configured via PReset within a few minutes.
R$ 3.840,70
R$ 3.840,70 Each (Sem VAT)
1
R$ 3.840,70
R$ 3.840,70 Each (Sem VAT)
1
Informações de estoque temporariamente indisponíveis.
Verifique novamente mais tarde.
Quantidade | Preço unitário |
---|---|
1 - 4 | R$ 3.840,70 |
5+ | R$ 3.782,82 |
Documentos Técnicos
Especificações
Brand
PR ElectronicsInput Type
Linear Resistance, RTD
Supply Voltage
8 → 35 V dc
Minimum Temperature Input
-200°C
Maximum Temperature Input
850°C
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+60°C
Series
6300
Depth
104mm
Hazardous Area Certification
ATEX
País de Origem
Denmark
Detalhes do produto
6333A - 2-wire Programmable Transmitter
PR Electronics 6333A 2-wire programmable temperature transmitter offers unrivalled performance in applications making heavy demands on accuracy to convert a wide array of input types to a 4 – 20 mA output signal. The 6333 transmitters provides unrivalled input versatility with galvanic isolation up to 1.5 kVAC for 2 & 3 Wire RTD and linear resistance signals. Input sensor redundancy function maintains process availability and safety in the event of primary sensor failure
The 6300 series transmitters are quickly and easily programmable to the specific application. Configuration via a standard PC and user-friendly software, PReset, available as a free download. Parameters for input, output, sensor error detection and process calibration can be configured via PReset within a few minutes.