Documentos Técnicos
Especificações
Brand
FlukeMaximum Pressure Measurement
100psi
Minimum Pressure Measurement
-12psi
Resolution
0.01 psi
Pressure Port Type
Differential
Model Number p
721
Current Loop Measurement
Yes
Maximum Operating Temperature
+50°C
Minimum Operating Temperature
-10°C
Weight
539g
Dimensions
58 x 110 x 200mm
Height
200mm
Length
58mm
Width
110mm
País de Origem
China
Detalhes do produto
Fluke 721 Precision Pressure Calibrator
The Fluke 721 Precision Pressure Calibrator with dual isolated pressure sensors is designed for gas flow calibration (custody transfer) applications, enabling users to take simultaneous static and differential pressure measurements with a single tool. The 721 can be configured by selecting either a 16 PSI (1.1 bar) or 36 PSI (2.48 bar) low pressure sensor and adding any of 7 high pressure ranges: 100, 300, 500, 1000, 1500, 3000, 5000 psi (6, 9, 20, 24.5, 69, 103.4, 200, 345 bar). Users can add temperature measurement with the separately available Pt-100 RTD probe Fluke-720RTD ( 796-1646 ).
Supplied with
Test leads, soft case, AA batteries (x4), manual, traceable calibration certificate
Standards
EN50082-1:1992 and EN55022:1994 Class B
R$ 89.714,70
R$ 89.714,70 Each (Sem VAT)
Calibration type
No Calibration
1
R$ 89.714,70
R$ 89.714,70 Each (Sem VAT)
Calibration type
No Calibration
1
Informações de estoque temporariamente indisponíveis.
Verifique novamente mais tarde.
Documentos Técnicos
Especificações
Brand
FlukeMaximum Pressure Measurement
100psi
Minimum Pressure Measurement
-12psi
Resolution
0.01 psi
Pressure Port Type
Differential
Model Number p
721
Current Loop Measurement
Yes
Maximum Operating Temperature
+50°C
Minimum Operating Temperature
-10°C
Weight
539g
Dimensions
58 x 110 x 200mm
Height
200mm
Length
58mm
Width
110mm
País de Origem
China
Detalhes do produto
Fluke 721 Precision Pressure Calibrator
The Fluke 721 Precision Pressure Calibrator with dual isolated pressure sensors is designed for gas flow calibration (custody transfer) applications, enabling users to take simultaneous static and differential pressure measurements with a single tool. The 721 can be configured by selecting either a 16 PSI (1.1 bar) or 36 PSI (2.48 bar) low pressure sensor and adding any of 7 high pressure ranges: 100, 300, 500, 1000, 1500, 3000, 5000 psi (6, 9, 20, 24.5, 69, 103.4, 200, 345 bar). Users can add temperature measurement with the separately available Pt-100 RTD probe Fluke-720RTD ( 796-1646 ).
Supplied with
Test leads, soft case, AA batteries (x4), manual, traceable calibration certificate
Standards