Fluke 902 Clampmeter, 200μA dc, Max Current 600A ac CAT III 600 V

Nº de Estoque RS: 131-303Marca: FlukePart Number: FLUKE-902/E
brand-logo
Ver tudo em Clamp Meters

Documentos Técnicos

Especificações

Brand

Fluke

Absolute Maximum AC Current Measurement

600A ac

Absolute Maximum DC Current Measurement

200µA dc

Absolute Maximum AC Voltage Measurement

600V ac

Absolute Maximum DC Voltage Measurement

600V dc

Absolute Maximum Resistance Measurement

9.999kΩ

Model Number

902

AC Current Measurement Resolution

100mA ac

DC Current Measurement Resolution

0.1µA dc

Best DC Current Accuracy

±1% + 5 Digits

Clamp Meter Type

Continuity, Crest Factor, Current, Resistance, Temperature, Voltage

Best AC Current Accuracy

±1% +5 digits

Best AC Voltage Accuracy

±1% + 5 Digits

Best DC Voltage Accuracy

±1% + 5 Digits

Functions Measured

AC Current, AC Voltage, Continuity, Crest Factor, DC Current, DC Voltage, Resistance, Temperature

True RMS

Yes

Safety Category Voltage

600V

Battery Type

AA

Safety Category

CAT III 600 V

Best Resistance Measurement Accuracy

±1.5% + 5 Digits

Display Type

LCD

Power Source

Battery

Length

238mm

Resistance Measurement Resolution

100mΩ

DC Voltage Measurement Resolution

0.1V dc

Maximum Conductor Size

30mm

Temperature Measurement Resolution

0.1°C

Absolute Maximum Temperature Measurement

+400°C

Maximum Operating Temperature

+50°C

Width

79mm

Dimensions

238 x 79 x 41mm

Best Temperature Measurement Accuracy

±1% + 0.8 °C

Minimum Operating Temperature

-10°C

Height

41mm

AC Voltage Measurement Resolution

0.1V ac

Battery Life

150 h

Weight

312g

Safety Category Level

CAT III

País de Origem

China

Detalhes do produto

Fluke 902 HVAC Current Clamp

Supplied with

2 AA alkaline batteries, 1 pair TL75 test leads, 80BK integrated DMM Temperature probe, users manual, soft carrying case.

HVAC Clampmeters

Você pode estar interessado em

Informações de estoque temporariamente indisponíveis.

Verifique novamente mais tarde.

Informações de estoque temporariamente indisponíveis.

P.O.A.

Fluke 902 Clampmeter, 200μA dc, Max Current 600A ac CAT III 600 V

P.O.A.

Fluke 902 Clampmeter, 200μA dc, Max Current 600A ac CAT III 600 V
Informações de estoque temporariamente indisponíveis.
Você pode estar interessado em

Documentos Técnicos

Especificações

Brand

Fluke

Absolute Maximum AC Current Measurement

600A ac

Absolute Maximum DC Current Measurement

200µA dc

Absolute Maximum AC Voltage Measurement

600V ac

Absolute Maximum DC Voltage Measurement

600V dc

Absolute Maximum Resistance Measurement

9.999kΩ

Model Number

902

AC Current Measurement Resolution

100mA ac

DC Current Measurement Resolution

0.1µA dc

Best DC Current Accuracy

±1% + 5 Digits

Clamp Meter Type

Continuity, Crest Factor, Current, Resistance, Temperature, Voltage

Best AC Current Accuracy

±1% +5 digits

Best AC Voltage Accuracy

±1% + 5 Digits

Best DC Voltage Accuracy

±1% + 5 Digits

Functions Measured

AC Current, AC Voltage, Continuity, Crest Factor, DC Current, DC Voltage, Resistance, Temperature

True RMS

Yes

Safety Category Voltage

600V

Battery Type

AA

Safety Category

CAT III 600 V

Best Resistance Measurement Accuracy

±1.5% + 5 Digits

Display Type

LCD

Power Source

Battery

Length

238mm

Resistance Measurement Resolution

100mΩ

DC Voltage Measurement Resolution

0.1V dc

Maximum Conductor Size

30mm

Temperature Measurement Resolution

0.1°C

Absolute Maximum Temperature Measurement

+400°C

Maximum Operating Temperature

+50°C

Width

79mm

Dimensions

238 x 79 x 41mm

Best Temperature Measurement Accuracy

±1% + 0.8 °C

Minimum Operating Temperature

-10°C

Height

41mm

AC Voltage Measurement Resolution

0.1V ac

Battery Life

150 h

Weight

312g

Safety Category Level

CAT III

País de Origem

China

Detalhes do produto

Fluke 902 HVAC Current Clamp

Supplied with

2 AA alkaline batteries, 1 pair TL75 test leads, 80BK integrated DMM Temperature probe, users manual, soft carrying case.

HVAC Clampmeters

Você pode estar interessado em