Key Instruments MR3000 Series Variable Area Flow Meter for Gas, 0.05 L/min Min, 0.5 L/min Max

Nº de Estoque RS: 198-2896Marca: Key InstrumentsPart Number: MR3A12BVBN
View all in Flow Sensors

Documentos Técnicos

Especificações

País de Origem

United States

Detalhes do produto

DEHN Data Signal Surge Arresters

DEHN data signal surge arresters for industrial process control circuits, the protection of the low voltage power supply and the I/O of PLC applications using sensors and transducers.

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Informações de estoque temporariamente indisponíveis.

Verifique novamente mais tarde.

Informações de estoque temporariamente indisponíveis.

R$ 2.245,73

Each (Sem VAT)

Key Instruments MR3000 Series Variable Area Flow Meter for Gas, 0.05 L/min Min, 0.5 L/min Max

R$ 2.245,73

Each (Sem VAT)

Key Instruments MR3000 Series Variable Area Flow Meter for Gas, 0.05 L/min Min, 0.5 L/min Max
Informações de estoque temporariamente indisponíveis.

Documentos Técnicos

Especificações

País de Origem

United States

Detalhes do produto

DEHN Data Signal Surge Arresters

DEHN data signal surge arresters for industrial process control circuits, the protection of the low voltage power supply and the I/O of PLC applications using sensors and transducers.

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.