Chauvin Arnoux CA 1631 Current & Voltage Calibrator, Max Voltage 20V 24 mA

Documentos Técnicos
Especificações
Brand
Chauvin ArnouxProduct Type
Current & Voltage Calibrator
Maximum Voltage Measurement
20V
Maximum Current Measurement
24mA
Accuracy
±0.015 %
Standards/Approvals
No
Power Source
Mains, Battery
Battery Type
AAA
Weight
472g
Height
45mm
Length
205mm
Maximum Operating Temperature
55°C
Hazardous Area Certification
No
Maximum Source Current
24mA
Maximum Source Voltage
20V
Width
97 mm
Minimum Source Voltage
0V
Minimum Source Current
0mA
Minimum Operating Temperature
-10°C
Model Number
CA 1631
Safety Category Voltage
30V
País de Origem
China
Detalhes do produto
Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631
These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.
Informações de estoque temporariamente indisponíveis.
R$ 19.352,24
R$ 19.352,24 Each (Sem VAT)
Calibration type
No Calibration
1
R$ 19.352,24
R$ 19.352,24 Each (Sem VAT)
Informações de estoque temporariamente indisponíveis.
Calibration type
No Calibration
1
Documentos Técnicos
Especificações
Brand
Chauvin ArnouxProduct Type
Current & Voltage Calibrator
Maximum Voltage Measurement
20V
Maximum Current Measurement
24mA
Accuracy
±0.015 %
Standards/Approvals
No
Power Source
Mains, Battery
Battery Type
AAA
Weight
472g
Height
45mm
Length
205mm
Maximum Operating Temperature
55°C
Hazardous Area Certification
No
Maximum Source Current
24mA
Maximum Source Voltage
20V
Width
97 mm
Minimum Source Voltage
0V
Minimum Source Current
0mA
Minimum Operating Temperature
-10°C
Model Number
CA 1631
Safety Category Voltage
30V
País de Origem
China
Detalhes do produto
Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631
These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.