Chauvin ArnouxResolution
0.01 mV
Calibrator Type
Thermocouple Calibrator
Best Accuracy
± 0.3°C
Thermocouple Type
B, E, J, K, N, R, S, T
Temperature Scale
Centigrade
B Type Thermocouple Maximum Temperature
+1800°C
B Type Thermocouple Minimum Temperature
+600°C
E Type Thermocouple Maximum Temperature
+950°C
E Type Thermocouple Minimum Temperature
-200°C
J Type Thermocouple Maximum Temperature
+1200°C
K Type Thermocouple Maximum Temperature
+1370°C
K Type Thermocouple Minimum Temperature
-200°C
Model Number p
CA 1621
R Type Thermocouple Maximum Temperature
+1750°C
T Type Thermocouple Maximum Temperature
+400°C
T Type Thermocouple Minimum Temperature
-200°C
E Type Thermocouple Temperature Range
-200 → +950 °C
Height
45mm
Weight
472g
S Type Thermocouple Minimum Temperature
-20°C
S Type Thermocouple Temperature Range
-20 → +1750 °C
S Type Thermocouple Maximum Temperature
+1750°C
T Type Thermocouple Temperature Range
-200 → +400 °C
J Type Thermocouple Temperature Range
-200 → +1200 °C
R Type Thermocouple Temperature Range
-20 → +1750 °C
Dimensions
205 x 97 x 45mm
Width
97mm
Length
205mm
R Type Thermocouple Minimum Temperature
-20°C
B Type Thermocouple Temperature Range
+600 → +1800 °C
K Type Thermocouple Temperature Range
-200 → +1370 °C
País de Origem
China
Detalhes do produto
Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631
These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.
Informações de estoque temporariamente indisponíveis.
Verifique novamente mais tarde.
R$ 21.011,12
Each (Sem VAT)
Calibration type
No Calibration
1
R$ 21.011,12
Each (Sem VAT)
Calibration type
No Calibration
1
Documentos Técnicos
Especificações
Brand
Chauvin ArnouxResolution
0.01 mV
Calibrator Type
Thermocouple Calibrator
Best Accuracy
± 0.3°C
Thermocouple Type
B, E, J, K, N, R, S, T
Temperature Scale
Centigrade
B Type Thermocouple Maximum Temperature
+1800°C
B Type Thermocouple Minimum Temperature
+600°C
E Type Thermocouple Maximum Temperature
+950°C
E Type Thermocouple Minimum Temperature
-200°C
J Type Thermocouple Maximum Temperature
+1200°C
K Type Thermocouple Maximum Temperature
+1370°C
K Type Thermocouple Minimum Temperature
-200°C
Model Number p
CA 1621
R Type Thermocouple Maximum Temperature
+1750°C
T Type Thermocouple Maximum Temperature
+400°C
T Type Thermocouple Minimum Temperature
-200°C
E Type Thermocouple Temperature Range
-200 → +950 °C
Height
45mm
Weight
472g
S Type Thermocouple Minimum Temperature
-20°C
S Type Thermocouple Temperature Range
-20 → +1750 °C
S Type Thermocouple Maximum Temperature
+1750°C
T Type Thermocouple Temperature Range
-200 → +400 °C
J Type Thermocouple Temperature Range
-200 → +1200 °C
R Type Thermocouple Temperature Range
-20 → +1750 °C
Dimensions
205 x 97 x 45mm
Width
97mm
Length
205mm
R Type Thermocouple Minimum Temperature
-20°C
B Type Thermocouple Temperature Range
+600 → +1800 °C
K Type Thermocouple Temperature Range
-200 → +1370 °C
País de Origem
China
Detalhes do produto
Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631
These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.