Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30

Nº de Estoque RS: 240-9140Marca: DoldPart Number: BA9010 3AC230/400V 1.5/3kW
brand-logo
Ver tudo em Motor Starters

Documentos Técnicos

Especificações

Brand

Dold

Power Rating

1.5 kW, 3 kW

Motor Starter Type

Soft Start

Voltage Rating

230 V ac, 400 V ac

Phase

1

IP Rating

IP30

Overall Length

121mm

Overall Width

45mm

Overall Depth

74mm

Series

BA9010

País de Origem

Germany

Detalhes do produto

Soft starter, BA9010

Warning


If devices are used in 230 V three-phase networks, the next higher power stage must be used for a given motor power, because the motor current determines the overall size of the device.
The starting current in the network cannot be lowered with these devices. In order to achieve this simultaneously with torque reduction, the BA9026 must be used, for example.
The BA9010 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.

Você pode estar interessado em
Informações de estoque temporariamente indisponíveis.

R$ 6.963,64

R$ 6.963,64 Each (Sem VAT)

Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30

R$ 6.963,64

R$ 6.963,64 Each (Sem VAT)

Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30
Informações de estoque temporariamente indisponíveis.

Informações de estoque temporariamente indisponíveis.

Verifique novamente mais tarde.

Você pode estar interessado em

Documentos Técnicos

Especificações

Brand

Dold

Power Rating

1.5 kW, 3 kW

Motor Starter Type

Soft Start

Voltage Rating

230 V ac, 400 V ac

Phase

1

IP Rating

IP30

Overall Length

121mm

Overall Width

45mm

Overall Depth

74mm

Series

BA9010

País de Origem

Germany

Detalhes do produto

Soft starter, BA9010

Warning


If devices are used in 230 V three-phase networks, the next higher power stage must be used for a given motor power, because the motor current determines the overall size of the device.
The starting current in the network cannot be lowered with these devices. In order to achieve this simultaneously with torque reduction, the BA9026 must be used, for example.
The BA9010 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.