Documentos Técnicos
Especificações
Brand
PD DevicesSuppressor Type
Surge Arrester
Maximum Voltage Rating
400 V ac
Mounting Type
Panel Mount
Maximum Surge Current
30kA
Series
600
Length
176mm
Depth
72mm
Height
110mm
Dimensions
176 x 72 x 110mm
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+70°C
Detalhes do produto
Distribution Surge Protector - 600 Series L & N Types
Transient Voltage Suppressors (Modules,Industrial)
Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.
Informações de estoque temporariamente indisponíveis.
Verifique novamente mais tarde.
P.O.A.
1
P.O.A.
1
Documentos Técnicos
Especificações
Brand
PD DevicesSuppressor Type
Surge Arrester
Maximum Voltage Rating
400 V ac
Mounting Type
Panel Mount
Maximum Surge Current
30kA
Series
600
Length
176mm
Depth
72mm
Height
110mm
Dimensions
176 x 72 x 110mm
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+70°C
Detalhes do produto
Distribution Surge Protector - 600 Series L & N Types
Transient Voltage Suppressors (Modules,Industrial)
Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.