PD Devices, 600 Surge Suppressor Unit 30kA Maximum Surge Current Mains Protector

Nº de Estoque RS: 375-9143Marca: PD DevicesPart Number: RS-DSP1/600
brand-logo
Ver tudo em Unidades de Supressores Surge

Documentos Técnicos

Especificações

Suppressor Type

Mains Protector

Maximum Surge Current

30kA

Series

600

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+70°C

País de Origem

United Kingdom

Detalhes do produto

Distribution Surge Protectors - 600 Series

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.

P.O.A.

PD Devices, 600 Surge Suppressor Unit 30kA Maximum Surge Current Mains Protector

P.O.A.

PD Devices, 600 Surge Suppressor Unit 30kA Maximum Surge Current Mains Protector

Informações de estoque temporariamente indisponíveis.

Informações de estoque temporariamente indisponíveis.

Documentos Técnicos

Especificações

Suppressor Type

Mains Protector

Maximum Surge Current

30kA

Series

600

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+70°C

País de Origem

United Kingdom

Detalhes do produto

Distribution Surge Protectors - 600 Series

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.