PR Electronics 9200 Series Pulse Isolator, Switch Input, Relay Output, 19.2/31.2 V dc Supply, UL, Zone, DNV GL, EAC,

Nº de Estoque RS: 827-5366Marca: PR ElectronicsPart Number: 9202B3A
brand-logo
Ver tudo em Signal Conditioners

Documentos Técnicos

Especificações

Product Type

Pulse Isolator

Input Signal Type

Switch

Output Signal Type

Relay

Supply Voltage

19.2/31.2 V dc

Hazardous Area Certification

UL, Zone, DNV GL, EAC, ATEX, Zone 2, EU RO marine, FM, IECEx

Mount Type

DIN Rail

Terminal Type

Screw

Maximum Operating Temperature

60°C

Minimum Operating Temperature

-20°C

IP Rating

IP20

Standards/Approvals

Zone 2-DIV 2, FM, NE 21, DNV-GL / EU-RO marine, NE 43, IECEX, UL 61010 / 508, EAC, ATEX, NAMUR, Zone 2

Series

9200

País de Origem

Denmark

Detalhes do produto

9202B Type - EX Pulse Isolator

PR Electronics 9202B pulse isolator for transmission of signals to the safe area from NAMUR sensors and mechanical switches installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 9202B uses transformer and optical isolation techniques to provide 2.6 kV galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 9202B are not electrically connected to the output pulse. The 9202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.

Besides providing isolation, the PR 9202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 9202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.

PR Electronics - Ex Interfaces

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more

Informações de estoque temporariamente indisponíveis.

R$ 4.291,75

R$ 4.291,75 Each (Sem VAT)

PR Electronics 9200 Series Pulse Isolator, Switch Input, Relay Output, 19.2/31.2 V dc Supply, UL, Zone, DNV GL, EAC,

R$ 4.291,75

R$ 4.291,75 Each (Sem VAT)

PR Electronics 9200 Series Pulse Isolator, Switch Input, Relay Output, 19.2/31.2 V dc Supply, UL, Zone, DNV GL, EAC,

Informações de estoque temporariamente indisponíveis.

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more

Documentos Técnicos

Especificações

Product Type

Pulse Isolator

Input Signal Type

Switch

Output Signal Type

Relay

Supply Voltage

19.2/31.2 V dc

Hazardous Area Certification

UL, Zone, DNV GL, EAC, ATEX, Zone 2, EU RO marine, FM, IECEx

Mount Type

DIN Rail

Terminal Type

Screw

Maximum Operating Temperature

60°C

Minimum Operating Temperature

-20°C

IP Rating

IP20

Standards/Approvals

Zone 2-DIV 2, FM, NE 21, DNV-GL / EU-RO marine, NE 43, IECEX, UL 61010 / 508, EAC, ATEX, NAMUR, Zone 2

Series

9200

País de Origem

Denmark

Detalhes do produto

9202B Type - EX Pulse Isolator

PR Electronics 9202B pulse isolator for transmission of signals to the safe area from NAMUR sensors and mechanical switches installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 9202B uses transformer and optical isolation techniques to provide 2.6 kV galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 9202B are not electrically connected to the output pulse. The 9202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.

Besides providing isolation, the PR 9202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 9202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.

PR Electronics - Ex Interfaces

Ideate. Create. Collaborate