PULS CP Redundancy Module DIN Rail Power Supply, 100 → 240V ac ac, dc Input, 24V dc dc Output, 10A Output, 240W

Nº de Estoque RS: 168-2939Marca: PULSPart Number: CP10.241-R2
brand-logo
View all in DIN Rail Power Supplies

Documentos Técnicos

Especificações

Brand

PULS

Type

Redundancy Module

Output Voltage

24V dc

Output Current

10A

AC or DC Input Voltage

ac, dc

AC or DC Output Voltage

dc

Input Voltage

100 → 240V ac

Power Rating

240W

Electrical Phase

1

Number of Outputs

1

Height

124mm

Width

39mm

Depth

117mm

Series

CP

Maximum Temperature

+70°C

Standards Met

ATEX, CE Certified, CSA Certified, cULus Listed, GL, IECEx, UL 508, UL 60950-1

Mounting Type

DIN Rail Mount

Minimum Temperature

-25°C

Ripple And Noise

50mV Pk-Pk

Output Voltage Adjustment Range

24 → 30V

Load Regulation

1000mV

Hazardous Area Certification

ATEX, IECEx

Special Features

Active Power Factor Correction (PFC), Built-in Decoupling Mosfet for 1+1 and n+1 Redundancy, Current Sharing Feature Included, DC-OK Relay Contact, Easy Fuse Breaking 3 Times Nominal Current for 12ms, Full Power Between -25°C and +60°C, Minimal Inrush Current Surge, Output Power Reserves, Safe HiccupPLUS Overload Mode

Informações de estoque temporariamente indisponíveis.

Verifique novamente mais tarde.

Informações de estoque temporariamente indisponíveis.

R$ 5.711,57

Each (Sem VAT)

PULS CP Redundancy Module DIN Rail Power Supply, 100 → 240V ac ac, dc Input, 24V dc dc Output, 10A Output, 240W

R$ 5.711,57

Each (Sem VAT)

PULS CP Redundancy Module DIN Rail Power Supply, 100 → 240V ac ac, dc Input, 24V dc dc Output, 10A Output, 240W
Informações de estoque temporariamente indisponíveis.

Documentos Técnicos

Especificações

Brand

PULS

Type

Redundancy Module

Output Voltage

24V dc

Output Current

10A

AC or DC Input Voltage

ac, dc

AC or DC Output Voltage

dc

Input Voltage

100 → 240V ac

Power Rating

240W

Electrical Phase

1

Number of Outputs

1

Height

124mm

Width

39mm

Depth

117mm

Series

CP

Maximum Temperature

+70°C

Standards Met

ATEX, CE Certified, CSA Certified, cULus Listed, GL, IECEx, UL 508, UL 60950-1

Mounting Type

DIN Rail Mount

Minimum Temperature

-25°C

Ripple And Noise

50mV Pk-Pk

Output Voltage Adjustment Range

24 → 30V

Load Regulation

1000mV

Hazardous Area Certification

ATEX, IECEx

Special Features

Active Power Factor Correction (PFC), Built-in Decoupling Mosfet for 1+1 and n+1 Redundancy, Current Sharing Feature Included, DC-OK Relay Contact, Easy Fuse Breaking 3 Times Nominal Current for 12ms, Full Power Between -25°C and +60°C, Minimal Inrush Current Surge, Output Power Reserves, Safe HiccupPLUS Overload Mode