Sollatek Voltage Suppressor 230V ac

Nº de Estoque RS: 707-9854Marca: SollatekPart Number: DSP1P-0
brand-logo
Ver tudo em Condicionadores de Energia

Documentos Técnicos

Especificações

Output Voltage

230V ac

Maximum Temperature

+85°C

Minimum Temperature

-40°C

País de Origem

China

Detalhes do produto

Distribution Panel Spike & Surge Device

Mains spike/surge protection devices that are ideal for protecting all sensitive electronic equipment.

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.

Informações de estoque temporariamente indisponíveis.

Verifique novamente mais tarde.

Informações de estoque temporariamente indisponíveis.

P.O.A.

Sollatek Voltage Suppressor 230V ac

P.O.A.

Sollatek Voltage Suppressor 230V ac
Informações de estoque temporariamente indisponíveis.

Documentos Técnicos

Especificações

Output Voltage

230V ac

Maximum Temperature

+85°C

Minimum Temperature

-40°C

País de Origem

China

Detalhes do produto

Distribution Panel Spike & Surge Device

Mains spike/surge protection devices that are ideal for protecting all sensitive electronic equipment.

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.