Teledyne LeCroyProbe Type
Differential
Attenuation
1:50, 1:500
Bandwidth
80MHz
Maximum Common Mode Input Voltage
1kV
Model Number p
HVD3206-6M
Model Number (p)
HVD3206-6M
Number of Probes
2
Safety Category Level
CAT I, CAT III
Safety Category Voltage
1000 Vrms, 1500 V dc, 2000 (DC + Peak AC) V
Safety Category
Cat I 2000 (DC + Peak AC) V, Cat III 1000 Vrms, Cat III 1500 V dc
Rise Time
4.4ns
País de Origem
United States
Detalhes do produto
Teledyne LeCroy High Voltage Differential Probe HDV3206-6M
Teledyne LeCroy 2kV, 120 MHz high voltage differential probe HVD3206-6M is specifically designed for 1500 V dc solar photovoltaic (PV) measurements per the IEC/EN 61010-031:2015 standard. The CMRR is exceptional out to very high frequencies, greatly improving measurement capability in noisy, high common-mode environments found in power electronics. The high CMRR combined with low probe noise and high offset capability enables measurement of very small control signals floating on high common-mode voltages. HVD probes provide 1% gain accuracy for precise voltage measurements. AutoZero capability ensures further measurement precision by allowing small offset drifts to be calibrated out of the measurement. The ProBus interface provides power and communication to the probe, eliminating the need for a separate power supply or batteries. Attenuation is automatically selected based on oscilloscope gain range (V/div) setting.
Supplied with
Safety alligator clips (1 red, 1 black), plunger pincer clips (1 red, 1 black), plunger hook clips (1 red, 1 black), plunger alligator clips (1 red, 1 black), spade terminals (1 red, 1 black), 6 kV safety alligator clips (1 red, 1 black)
P.O.A.
1
P.O.A.
1
Informações de estoque temporariamente indisponíveis.
Verifique novamente mais tarde.
Documentos Técnicos
Especificações
Brand
Teledyne LeCroyProbe Type
Differential
Attenuation
1:50, 1:500
Bandwidth
80MHz
Maximum Common Mode Input Voltage
1kV
Model Number p
HVD3206-6M
Model Number (p)
HVD3206-6M
Number of Probes
2
Safety Category Level
CAT I, CAT III
Safety Category Voltage
1000 Vrms, 1500 V dc, 2000 (DC + Peak AC) V
Safety Category
Cat I 2000 (DC + Peak AC) V, Cat III 1000 Vrms, Cat III 1500 V dc
Rise Time
4.4ns
País de Origem
United States
Detalhes do produto
Teledyne LeCroy High Voltage Differential Probe HDV3206-6M
Teledyne LeCroy 2kV, 120 MHz high voltage differential probe HVD3206-6M is specifically designed for 1500 V dc solar photovoltaic (PV) measurements per the IEC/EN 61010-031:2015 standard. The CMRR is exceptional out to very high frequencies, greatly improving measurement capability in noisy, high common-mode environments found in power electronics. The high CMRR combined with low probe noise and high offset capability enables measurement of very small control signals floating on high common-mode voltages. HVD probes provide 1% gain accuracy for precise voltage measurements. AutoZero capability ensures further measurement precision by allowing small offset drifts to be calibrated out of the measurement. The ProBus interface provides power and communication to the probe, eliminating the need for a separate power supply or batteries. Attenuation is automatically selected based on oscilloscope gain range (V/div) setting.
Supplied with
Safety alligator clips (1 red, 1 black), plunger pincer clips (1 red, 1 black), plunger hook clips (1 red, 1 black), plunger alligator clips (1 red, 1 black), spade terminals (1 red, 1 black), 6 kV safety alligator clips (1 red, 1 black)