Telemecanique Sensors XY2CE Rope Pull Switch, 2 x 35 → 2 x 100m, 2NO/2NC

Nº de Estoque RS: 130-0875Marca: Telemecanique SensorsPart Number: XY2CEDA196H7
brand-logo
View all in Rope Pull Switches

Documentos Técnicos

Especificações

Normal State Configuration

2NO/2NC

Cable Length

2 x 35 → 2 x 100m

IP Rating

IP66

Number of Poles

DPST

Series

XY2CE

Range

Preventa XY2

Length

285mm

Width

106mm

Depth

142mm

Housing Material

Stainless Steel

Hazardous Area Certification

ATEX

Standards Met

CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508

Conduit Entry

1/2 in NPT

Maximum AC Voltage

24 → 130V

Maximum Operating Temperature

+70°C

Maximum DC Voltage

24 → 130V

Dimensions

285 x 106 x 142mm

Minimum Operating Temperature

-25°C

Detalhes do produto

Telemecanique XY2CED Emergency Stop Dual Rope Pull Switches

Telemecanique XY2CED emergency stop dual rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. These dual rope pull switches feature double anchor points and can support up to 2 x 100 m with supports and pulleys. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the tripwire breaking.

Informações de estoque temporariamente indisponíveis.

Verifique novamente mais tarde.

Informações de estoque temporariamente indisponíveis.

R$ 8.620,20

Each (Sem VAT)

Telemecanique Sensors XY2CE Rope Pull Switch, 2 x 35 → 2 x 100m, 2NO/2NC

R$ 8.620,20

Each (Sem VAT)

Telemecanique Sensors XY2CE Rope Pull Switch, 2 x 35 → 2 x 100m, 2NO/2NC
Informações de estoque temporariamente indisponíveis.

Documentos Técnicos

Especificações

Normal State Configuration

2NO/2NC

Cable Length

2 x 35 → 2 x 100m

IP Rating

IP66

Number of Poles

DPST

Series

XY2CE

Range

Preventa XY2

Length

285mm

Width

106mm

Depth

142mm

Housing Material

Stainless Steel

Hazardous Area Certification

ATEX

Standards Met

CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508

Conduit Entry

1/2 in NPT

Maximum AC Voltage

24 → 130V

Maximum Operating Temperature

+70°C

Maximum DC Voltage

24 → 130V

Dimensions

285 x 106 x 142mm

Minimum Operating Temperature

-25°C

Detalhes do produto

Telemecanique XY2CED Emergency Stop Dual Rope Pull Switches

Telemecanique XY2CED emergency stop dual rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. These dual rope pull switches feature double anchor points and can support up to 2 x 100 m with supports and pulleys. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the tripwire breaking.