Documentos Técnicos
Especificações
Brand
Chauvin ArnouxRatio Range CT
0.8000 → 1000.0
Ratio Range (CT)
0.8000 → 1000.0
Ratio Range VT/PT
0.8000 → 8000.0 :1
Ratio Range (VT/PT)
0.8000 → 8000.0 :1
Excitation Voltage VT/PT
32Vrms
Excitation Voltage (VT/PT)
32Vrms
Excitation Signal CT
0 → 1 A, 0.1 → 4.5Vrms
Excitation Signal (CT)
0 → 1 A, 0.1 → 4.5Vrms
Test Frequencies
70Hz
Excitation Current Display
0 → 1A
Test Results Storage
10 000
Battery Life
10 h
Power Source
Battery
Maximum Operating Temperature
+50°C
Minimum Operating Temperature
-10°C
IP Rating
IP40, IP53
Model Number (p)
DTR 8510
Length
272mm
País de Origem
United States
Detalhes do produto
DTR 8510 Digital Transformer Ratiometer
The DTR 8510 Dogital Transformer Ratiometer is fully automatic and uses the IEEE C57.12-90™-2006 test method. The DTR 8510 is a portable digital transformer ratiometer designed for on-site testing of power, potential and current transformers.When connected to a non-energized transformer, the DTR 8510 accurately measures the primary-to-secondary turns ratio, while simultaneouslydisplaying the polarity and excitation current.
Supplied with
DataViewⓇ analysis software
Standards
EN 61010-1, 50V CAT IV, Pollution Degree 2
Informações de estoque temporariamente indisponíveis.
Verifique novamente mais tarde.
R$ 105.671,28
Each (Sem VAT)
1
R$ 105.671,28
Each (Sem VAT)
1
Documentos Técnicos
Especificações
Brand
Chauvin ArnouxRatio Range CT
0.8000 → 1000.0
Ratio Range (CT)
0.8000 → 1000.0
Ratio Range VT/PT
0.8000 → 8000.0 :1
Ratio Range (VT/PT)
0.8000 → 8000.0 :1
Excitation Voltage VT/PT
32Vrms
Excitation Voltage (VT/PT)
32Vrms
Excitation Signal CT
0 → 1 A, 0.1 → 4.5Vrms
Excitation Signal (CT)
0 → 1 A, 0.1 → 4.5Vrms
Test Frequencies
70Hz
Excitation Current Display
0 → 1A
Test Results Storage
10 000
Battery Life
10 h
Power Source
Battery
Maximum Operating Temperature
+50°C
Minimum Operating Temperature
-10°C
IP Rating
IP40, IP53
Model Number (p)
DTR 8510
Length
272mm
País de Origem
United States
Detalhes do produto
DTR 8510 Digital Transformer Ratiometer
The DTR 8510 Dogital Transformer Ratiometer is fully automatic and uses the IEEE C57.12-90™-2006 test method. The DTR 8510 is a portable digital transformer ratiometer designed for on-site testing of power, potential and current transformers.When connected to a non-energized transformer, the DTR 8510 accurately measures the primary-to-secondary turns ratio, while simultaneouslydisplaying the polarity and excitation current.
Supplied with
DataViewⓇ analysis software
Standards
EN 61010-1, 50V CAT IV, Pollution Degree 2