Documentos Técnicos
Especificações
Brand
FlukeProduct Type
Multimeter
Multimeter Type
Digital
Resistance Resolution
100mΩ
Model Number
116
Display Type
Digital
Functions Measured
AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature
Maximum DC Voltage Measurement
600V dc
Maximum DC Current Measurement
600μA dc
Maximum AC Current Measurement
600μA ac
Maximum Resistance Measurement
40mΩ
Maximum AC Voltage Measurement
600V ac
True RMS
Yes
AC Voltage Accuracy
±1 % rdg + 3 Digits
DC Current Accuracy
±1 % rdg + 2 Digits
AC Current Accuracy
±1.5 % rdg + 3 Digits
DC Voltage Accuracy
±0.5 % rdg + 2 Digits
AC Voltage Resolution
0.1mV ac
AC Current Resolution
0.1μA ac
DC Current Resolution
0.1μA dc
DC Voltage Resolution
0.1 mV dc
Maximum Frequency
1kHz
Minimum Operating Temperature
-10°C
Resistance Measurement Accuracy
±1.5 % rdg + 2 Digits
Maximum Operating Temperature
50°C
Battery Life
400h
Height
167mm
Length
46mm
Weight
550g
Standards/Approvals
No
Width
84mm
Safety Category Level
CAT III
Battery Type
Alkaline
Safety Category Voltage
600V
Detalhes do produto
This multimeter is a Compact handheld instrument designed for HVAC and industrial electrical troubleshooting, combining temperature measurement and microamp capability to assess flame sensors and system performance. It provides true-RMS measurements for accurate readings on non-sinusoidal signals and is intended for field use in automation, electronics and mechanical environments.
It uses a 9V alkaline cell and typically runs for around 400h without the backlight.
A large white LED backlight illuminates the display for work in dim environments.
It is rated for CAT III 600V with 6kV Peak surge protection per IEC 61010-1 and pollution degree 2.
Capacitance is measured from 1nF to 9999μF with specified accuracy changing above 100μF.
Min/Max/Average logging with elapsed time records signal fluctuations during monitoring.
From Fluke, the 116 is designed for heating, ventilation and Air conditioning (HVAC) engineers. The model includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.
TL75 Test Leads, 80BK Integrated Temperature Probe, holster, users manual and 9V battery (installed)
Informações de estoque temporariamente indisponíveis.
R$ 8.262,61
R$ 8.262,61 Each (Sem VAT)
Calibration type
No Calibration
1
R$ 8.262,61
R$ 8.262,61 Each (Sem VAT)
Informações de estoque temporariamente indisponíveis.
Calibration type
No Calibration
1
Documentos Técnicos
Especificações
Brand
FlukeProduct Type
Multimeter
Multimeter Type
Digital
Resistance Resolution
100mΩ
Model Number
116
Display Type
Digital
Functions Measured
AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature
Maximum DC Voltage Measurement
600V dc
Maximum DC Current Measurement
600μA dc
Maximum AC Current Measurement
600μA ac
Maximum Resistance Measurement
40mΩ
Maximum AC Voltage Measurement
600V ac
True RMS
Yes
AC Voltage Accuracy
±1 % rdg + 3 Digits
DC Current Accuracy
±1 % rdg + 2 Digits
AC Current Accuracy
±1.5 % rdg + 3 Digits
DC Voltage Accuracy
±0.5 % rdg + 2 Digits
AC Voltage Resolution
0.1mV ac
AC Current Resolution
0.1μA ac
DC Current Resolution
0.1μA dc
DC Voltage Resolution
0.1 mV dc
Maximum Frequency
1kHz
Minimum Operating Temperature
-10°C
Resistance Measurement Accuracy
±1.5 % rdg + 2 Digits
Maximum Operating Temperature
50°C
Battery Life
400h
Height
167mm
Length
46mm
Weight
550g
Standards/Approvals
No
Width
84mm
Safety Category Level
CAT III
Battery Type
Alkaline
Safety Category Voltage
600V
Detalhes do produto
This multimeter is a Compact handheld instrument designed for HVAC and industrial electrical troubleshooting, combining temperature measurement and microamp capability to assess flame sensors and system performance. It provides true-RMS measurements for accurate readings on non-sinusoidal signals and is intended for field use in automation, electronics and mechanical environments.
It uses a 9V alkaline cell and typically runs for around 400h without the backlight.
A large white LED backlight illuminates the display for work in dim environments.
It is rated for CAT III 600V with 6kV Peak surge protection per IEC 61010-1 and pollution degree 2.
Capacitance is measured from 1nF to 9999μF with specified accuracy changing above 100μF.
Min/Max/Average logging with elapsed time records signal fluctuations during monitoring.
From Fluke, the 116 is designed for heating, ventilation and Air conditioning (HVAC) engineers. The model includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.
TL75 Test Leads, 80BK Integrated Temperature Probe, holster, users manual and 9V battery (installed)