Omron G9SA Emergency Stop Safety Relay, 24V ac/dc, Single/Dual-Channel, 3 Safety Contacts

Nº de Estoque RS: 549-609Marca: OmronPart Number: G9SA-301 AC/DC24
brand-logo
Ver tudo em Relés de Segurança

Documentos Técnicos

Especificações

Brand

Omron

Supply Voltage

24V ac/dc

Number of Channels

1, 2

Safety Contacts

3

Function

Emergency Stop

Auxiliary Contacts

1

Reset Method

Automatic

Safety Category ISO 13849-1

4

Safety Category (ISO 13849-1)

4

PL ISO 13849-1

e

PL (ISO 13849-1)

e

Standards Met

CE, CSA

Series

G9SA

Width

45mm

Depth

111mm

Performance Level

e

Length

76mm

País de Origem

China

Detalhes do produto

G9SA, Safety Relays, Expandable

The G9SA family offers a line-up of compact and expandable safety relay units. Modules with safe OFF-delay timing are available as well as a two hand controller. Simple multiplication of safety contacts is possible by using the connection on the front.

Approvals

UL, CSA

Standards

EN954-1, EN60204-1, EN574 (-TH301), UL508, CSA C22.2 No. 14

Informações de estoque temporariamente indisponíveis.

Verifique novamente mais tarde.

Informações de estoque temporariamente indisponíveis.

R$ 5.393,45

Each (Sem VAT)

Omron G9SA Emergency Stop Safety Relay, 24V ac/dc, Single/Dual-Channel, 3 Safety Contacts

R$ 5.393,45

Each (Sem VAT)

Omron G9SA Emergency Stop Safety Relay, 24V ac/dc, Single/Dual-Channel, 3 Safety Contacts
Informações de estoque temporariamente indisponíveis.

Documentos Técnicos

Especificações

Brand

Omron

Supply Voltage

24V ac/dc

Number of Channels

1, 2

Safety Contacts

3

Function

Emergency Stop

Auxiliary Contacts

1

Reset Method

Automatic

Safety Category ISO 13849-1

4

Safety Category (ISO 13849-1)

4

PL ISO 13849-1

e

PL (ISO 13849-1)

e

Standards Met

CE, CSA

Series

G9SA

Width

45mm

Depth

111mm

Performance Level

e

Length

76mm

País de Origem

China

Detalhes do produto

G9SA, Safety Relays, Expandable

The G9SA family offers a line-up of compact and expandable safety relay units. Modules with safe OFF-delay timing are available as well as a two hand controller. Simple multiplication of safety contacts is possible by using the connection on the front.

Approvals

UL, CSA

Standards

EN954-1, EN60204-1, EN574 (-TH301), UL508, CSA C22.2 No. 14