Documentos Técnicos
Especificações
Brand
BurkertProduct Type
Flow Controller
Terminal Type
Cable Plug
Control Output
PNP
Mount Type
Compact
Maximum Pipe Diameter
65mm
Minimum Operating Temperature
-15°C
Maximum Supply Voltage
36V dc
Maximum Operating Temperature
60°C
Hazardous Area Certification
ATEX
Standards/Approvals
EMC
Current Rating
100mA
Series
8030
País de Origem
France
Detalhes do produto
The Burkert flow transmitter + sensor has an open collector (PNP/NPN) type output and cable plug electrical connection device. It is designed to measure the continuous flow of liquids. Its operating voltage rating ranges between 12VDC and 36VDC. This sensor produces a signal which can be transmitted and processed enabling the end-user to get a flow measurement. The division is performed by measuring the pulses for the required unit of flow (litres per min.) and then, by the use of four rotary switches on the divider unit (discontinued) - that it is on top of the transmitter to divide signals enabling the output to be tailored to individual requirements. The correct dividing factor can be set up to give the required pulses out for the flow rate.
Informações de estoque temporariamente indisponíveis.
R$ 4.105,27
R$ 4.105,27 Each (Sem VAT)
1
R$ 4.105,27
R$ 4.105,27 Each (Sem VAT)
Informações de estoque temporariamente indisponíveis.
1
Documentos Técnicos
Especificações
Brand
BurkertProduct Type
Flow Controller
Terminal Type
Cable Plug
Control Output
PNP
Mount Type
Compact
Maximum Pipe Diameter
65mm
Minimum Operating Temperature
-15°C
Maximum Supply Voltage
36V dc
Maximum Operating Temperature
60°C
Hazardous Area Certification
ATEX
Standards/Approvals
EMC
Current Rating
100mA
Series
8030
País de Origem
France
Detalhes do produto
The Burkert flow transmitter + sensor has an open collector (PNP/NPN) type output and cable plug electrical connection device. It is designed to measure the continuous flow of liquids. Its operating voltage rating ranges between 12VDC and 36VDC. This sensor produces a signal which can be transmitted and processed enabling the end-user to get a flow measurement. The division is performed by measuring the pulses for the required unit of flow (litres per min.) and then, by the use of four rotary switches on the divider unit (discontinued) - that it is on top of the transmitter to divide signals enabling the output to be tailored to individual requirements. The correct dividing factor can be set up to give the required pulses out for the flow rate.